Part of the Energy Revolution
|
E85 Flex Fuel Conversion Kit Specifications
|
Input
Input Voltage Range 15.5-40 VDC
Input Transient 10-50 V for 10 s,
600 V for 10 µs 50 Ω source
resistance per MIL-STD-704A,
100 V for 50 ms 0.5
Ω source resistance per
MIL-STD-1275A, ±250 V for 100
µs as per MIL-STD-1275A
Output
Output Voltage Clamped <50 VDC
Output Power 50 W max
Inhibit Off = TTL Low or short circuit,
On = TTL High or open circuit
General
Efficiency 97% typical
Resistance 0.25 Ω Input to Output,
<0.1 Ω Case to Case pin at 10 A
Power Dissapation Inhibited 0.1 W
Inrush Current 25 A at 28 Vin
Fusing External fusing required
MTBF 846 kHrs to MIL-HDBK-217F GF at +40 °C
Environmental
Operating Temperature -40 ºC to +85 ºC ambient,
-40 °C to +100 °C case.
Extended temperature range:
-55 ºC to +85 ºC ambient,
-55 °C to +100 °C case
Storage Temperature -50 ºC to +125 ºC
Operating Altitude Tested to 70000 Ft (21336 m)
Operating Humidity 88% relative humidity,
240h MIL-STD-810D method 507.2
Shock 100 g MIL-STD-810D Method 516.3
Vibration 10 to 2000 Hz
MIL-STD-810D Method 514.3
Bump 2000 Bumps in each axes 40 g
MIL-STD-810D Method 516.3
Salt Atmosphere 48 hours MIL-STD-810E Method 509.1
EMC and Safety
Conducted Emissions EN55022 Conducted Level B, MIL-STD 461E:
CE101 & CE102
(These standards are met
when used in conjuction with the MTC Series)
Immunity MIL-STD-704E,
MIL-STD-704A & MIL-STD-1275A/B/C/D
(These standards
are met when used in conjuction with the MTC Series)
Conducted Susceptibility MIL-STD-461E CS101, CS114, CS115, CS116
(These standards are met when used in
conjuction with the MTC Series)