E85 Flex Fuel Conversion Kit Specifications

Input
Input Voltage Range                            15.5-40 VDC

Input Transient                                     10-50 V for 10 s,
                            600 V for 10 µs 50 Ω source
                            resistance per MIL-STD-704A,
                            100 V for 50 ms 0.5
                            Ω source resistance per
                            MIL-STD-1275A, ±250 V for 100

                            µs as per MIL-STD-1275A

Output
Output Voltage                                     Clamped <50 VDC

Output Power                                        50 W max

Inhibit                                                    Off = TTL Low or short circuit,
                            On = TTL High or open circuit

General
Efficiency                                              97% typical

Resistance                                            0.25 Ω Input to Output,
                             <0.1 Ω Case to Case pin at 10 A

Power Dissapation Inhibited                  0.1 W

Inrush Current                                      25 A at 28 Vin

Fusing                                                  External fusing required

MTBF                                                    846 kHrs to MIL-HDBK-217F GF at +40 °C  

Environmental
Operating Temperature                         -40 ºC to +85 ºC ambient,
                             -40 °C to +100 °C case.
                             Extended temperature range:
                             -55 ºC to +85 ºC ambient,
                             -55 °C to +100 °C case

Storage Temperature                           -50 ºC to +125 ºC

Operating Altitude                                 Tested to 70000 Ft (21336 m)

Operating Humidity                                88% relative humidity,
                              240h MIL-STD-810D method 507.2

Shock                                                   100 g MIL-STD-810D Method 516.3

Vibration                                               10 to 2000 Hz
                              MIL-STD-810D Method 514.3

Bump                                                    2000 Bumps in each axes 40 g
                              MIL-STD-810D Method 516.3

Salt Atmosphere                                   48 hours MIL-STD-810E Method 509.1

EMC and Safety
Conducted Emissions                            EN55022 Conducted Level B, MIL-STD 461E:
                              CE101 & CE102
                              (These standards are met
                               when used in conjuction with the MTC Series)

Immunity                                                MIL-STD-704E,
                              MIL-STD-704A & MIL-STD-1275A/B/C/D
                              (These standards
                               are met when used in conjuction with the MTC Series)

Conducted Susceptibility                        MIL-STD-461E CS101, CS114, CS115, CS116
                               (These standards are met when used in
                                conjuction with the MTC Series)
Jonny Energy
Copyright 2009 Jonny Energy LLC  Chicago, Illinois (312) 608-4441
Contact Email info@jonnyenergy.com
Private Policy and Terms of Use
About Jonny Energy